In this chapter, a power control system for a wound rotor induction generator has been explained. This power control system has realized a control method using a rotating reference frame fixed on the air-gap flux of the generator. Application of such a system allows control of the active and reactive power of generators independently and stably. So, a two-step process is presented here. The first step is to acquire the complex power expression (and thus the active and reactive power expressions) for an induction machine in space vector notation and in two-axes system. Then, a computer aided circuit is given to realize the power and current control by analyzing them. Also, the results of an experiment given in literature are shown to be able to compare the results.