Subcooled flow boiling CHF correlations
1. Introduction
Flow boiling has an extremely high heat transfer coefficient, and is applied in variety of practices. However, once the heat flux exceeds a certain high level the heated surface can no longer support continuous liquid contact, associated with substantial reduction in the heat transfer efficiency. It may result in a sudden rise of surface temperature in a heat flux controlled system, or a drastic decrease in power transferred in a temperature controlled system. This phenomenon is called the boiling crisis, and the maximum heat flux just before the boiling crisis is usually referred to as critical heat flux (CHF).
Depending on the flow regimes, two types of CHF are classified: (i) in subcooled or low quality region the CHF is characterized by the transition from nucleate boiling to film boiling, and it is termed as the departure from nucleate boiling (DNB); (ii) in higher quality region the CHF is characterized by the dryout of liquid film of annular flow. The DNB and dryout have substantially different mechanisms, and are generally cataloged as the first and the second kind of critical heat flux, respectively (Tong and Tang, 1997).
The CHF is an important subject to many engineering applications. Especially, in a nuclear reactor the occurrence of critical heat flux could lead to a failure of fuel element, and thus the CHF is a major limit for the reactor safety. During past five decades the CHF has been investigated extensively over the world theoretically and experimentally (IAEA-TECDOC-1203, 2001). A great number of empirical correlations and physical models have been proposed. In recent years, a Look-Up Table method (LUT) is widely accepted due to its advantages of higher accuracy, wider range of application, correct asymptotic trend and convenience for updating (Groeneveld, et al., 1996). This table is applied in the system code RELAP5 for reactor safety analysis. The LUT contains a tabulation of normalized CHF data of a uniformly heated tube of 8 mm in diameter at discrete local parameters of pressure, mass flux and quality. Several correction factors are incorporated for utilization of the LUT in other conditions to account for the effects of diameter, bundle, spacer, flux distribution, flow orientation, etc.. Unfortunately, there exists a scarcity of CHF data in low pressure/low flow/ subcooled region, as shown in Fig.1. Because of the extreme complexity of the phenomenon and the lack of adequate knowledge of the mechanisms, all these predictive methods are heavily relied on experimental data, and can not be extrapolated out of their ranges with confidence.
In China Institute of Atomic Energy (CIAE), in the past four decades a great number of CHF experimental data of subcooled boiling of flowing water were obtained in tubes and annuli at lower pressure with different diameter or gap to support the designs of research reactors, HFR and CARR, which were first put into operation in 1980 and 2011, respectively. In recent years the experiments were extended to the region of near-critical pressure with lower flow for the R&D of Supercritical Water-Cooled Reactor (SCWR). In these experiments the CHF (DNB) phenomena are studied with emphases on lower pressure and higher pressure with lower flow. The characteristics and parametric trends of the CHF are clarified, and the physical models are derived.
2. Parametric trends
A comprehensive review on the subcooled flow boiling CHF was given by Berglest (1977). As concluded, the effect of heating length disappears when exceeding 200 mm and the subcooled boiling CHF depends only on local parameter (“local condition hypothesis”). The CHF increases with the local mass flux and subcooling increasing. The effect of pressure is more complicated: the CHF increases with pressure in low pressure region, is relatively constant over an intermediate range of pressure, and decreases in high pressure region. The effect of geometry on CHF is observed in many experiments, and is accounted by a factor f = (De/8)n, in which De is the hydraulic diameter in mm. Different value of the exponent n is obtained from different experiments, ranging from -0.1 to -0.5. For applying the LUT in reactor safety analysis code RELAP5 the value of n = -0.5 is used. While for annulus or rectangular channels the effect of gap width is not observed in many experiments.
In Savannah River lab and Columbia University the subcooled CHF experiments were conducted with D2O and H2O coolant and aluminum and stainless-steel heaters (Knoebel et al., 1973). It was concluded that the CHF for D2O is 16% greater than for H2O at constant subcooling and velocity, and the CHF of aluminum heaters is a minimum of 20% greater than for stainless steel.
Some typical subcooled boiling CHF correlations are listed in Tab.1. Similar trends of the CHF with the flow rate and subcooling are represented in various correlations, but the degrees of these effects are different significantly. The present investigation has revealed that these effects are inter-dependent, associated with complicated parametrical trends for different regions of conditions.
3. Experiment
3.1. Technique
The onset of critical heat flux is characterized by a drastic increase in the wall temperature. For subcooled flow boiling of water with lower pressure the critical heat flux is higher and it could lead to a failure of the heated wall rapidly. This kind of CHF is also called as “fast burnout”. In experiment the onset of CHF is usually detected by thermocouples for protection of the test section. However, the occurrence of CHF generally initiates from a small area (or a spot), and for a test section of larger size the CHF spot can not be expected exactly. This presents a challenge for prevention of the test section from burnout. For this condition the photocell has advantage for the detection of CHF.
In the present experiments the pressure and flow rate are kept at constant, and the CHF is approached by increasing slowly the water temperature or the power to test section. When the CHF occurs and the wall temperature exceeds about 500°C, the photocell produces an output, which switches off the power supply to test section. This technique is used by author for all the experiments in tubes and annuli.
3.2. Experimental results
3.2.1. Higher pressure CHF (Chen et al., 2011)
Experiment was performed in an uniformly heated inconel tube of 7.95 mm in diameter and 0.8 m in heating length, covering the ranges of pressure of
For the present low flow condition the CHF is related to the inlet condition, characterizing the mechanism of total power dominant. Totally, 193 data are obtained, and are formulated as the following empiric correlation,
where
and
where
The effects of mass flux, inlet subcooling and pressure are exemplified in Fig.3 and 4. The CHF decreases substantially with mass flux decreasing. As can be seen, at G > 1200 kg/m2s the data are close to the prediction of 96-CHF Look-Up Table (LUT), but at low mass flux the data are overpredicted significantly (Fig.3). For lower pressure the effects of inlet subcooling and mass flux are stronger than higher pressure, associated with complicated trend of the CHF with pressure. For G > 1200 kg/m2s higher CHF corresponds to lower pressure, especially in high subcooling region (Fig.4(a)). For G= 700 – 1200 kg/m2s the results of
3.2.2. Lower pressure CHF
Experimental data were obtained in uniformly heated stainless-steel tubes of 5.17, 8.05, 10.0 and 16.0 mm in diameter, covering the ranges of pressure p = 0.13 – 1.92 MPa, velocity V = 1.47 – 22.32 m/s, as listed in Tab.2.
Fig.5 and 6 exemplify the variations of critical heat flux with local velocity and subcooling for different pressures. The CHF increases strongly with the velocity increasing (Fig.5). For subcooling higher than about 30 K, the CHF exhibits an approximately linear increase with increase of subcooling. In medium subcooling region the CHF is not different greatly between different pressures. For p < 0.3 MPa the trend of CHF with subcooling is steeper than that of higher pressure, so that in low subcooling region lower CHF is obtained at lower pressure (Fig.6). The CHF also exhibits a general increase trend with the decrease of diameter, and at lower velocity this effect appears stronger than higher velocity.
No. | Diameter D (mm) | Length L (mm) | Pressure P (MPa) | Velocity V (m/s) | Subcooling △Ts (K) | Number of data |
1 | 5.17 | 255 | 0.13-1.78 | 3.26-22.32 | 6.2-89.6 | 62 |
2 | 8.05 | 383, 396 | 0.14-1.92 | 1.85-16.05 | 8.3 – 88.2 | 65 |
3 | 10.0 | 295, 400 | 0.15-1.66 | 3.39-9.26 | 30.3-89.5 | 53 |
4 | 16.0 | 295, 390 | 0.19-1.29 | 1.47-13.7 | 36.7-108.7 | 56 |
224 CHF data of subcooling higher than 35 K are formulated by the following empiric correlation with local parameters of p, V, △Ts and D:
where the pressure
Low subcooling (Chen et al., 2005).
The experiment was performed in a stainless-steel tube of D=15.9 mm with emphasis on the CHF characteristic in low subcooling region. The conditions cover the ranges of pressure of 0.2 - 1.7 MPa and velocity of 2.2 - 13.2 m/s. Fig.8 exemplifies the variations of CHF with subcooling. For p > 1.0 MPa, the CHF decreases with △Ts decreasing monotonously. For p < 0.3 MPa, however, this trend breaks at a certain low value of subcooling, and it turns to increase at further low subcooling. The subcooling at the minimum CHF varies from 13 to 30 K with lower value corresponding to lower velocity.
This behavior was also observed in the author’s experiment in annuli and other similar experiments (Zeigarnik, 1994, Knoeble et al., 1973). It can be attributed to the onset of net vapor generation (NVG) or the onset of significant voiding (OSV). For p < 0.3 MPa, the vapor density is very small, so that in NVG regime the volumetric flow rate increases essentially, associated with a considerable increase in the liquid velocity. Therefore, the bubbles generated on the heated surface are more likely to enter into the liquid core, resulting in higher CHF. At high pressure the vapor density is much higher, and hence the CHF behavior could not vary distinctly in low subcooling region.
The NVG or OSV was generally identified by a sharper increase in the pressure drop. The following type of empiric correlation was derived
with the values of n ranging from 0.5 to 1.0. (Siman-Tov, et al. 1995). For the present experimental condition most correlations predict the OSV at subcooling of below 40 K.
Fig.9 shows the variations of pressure drop with the increase of exit temperature. As seen, before the OSV the pressure drop increases slowly with the temperature increasing. After the OSV this trend varies distinctly. Especially at low pressure it is much steeper than that at higher pressure.
In a reactor core the fuel elements are located in parallel channels. Therefore, at low pressure with low subcooling the OSV could result in flow instability or flow excursion (FE), characterized by a continuous decrease of flow rate in a channel. This could eventually lead to a failure of fuel element. Therefore, for reactor safety the limit of OSV is taken as a cr1terion in combination with the limit of minimum ratio of DNB
3.2.2.2. CHF in annuli
Single-side heating (Chen et al., 2004)
Experiments were performed in 8 annuli made of stainless-steel tubes with single-side heating. The diameter of outer wall is 16, 32 or 70mm and gap width is 2 to 4mm. Great majority of CHF data were obtained at outer wall and less at inner wall, covering the range of pressure of 0.17 - 1.8MPa, mass flux of 1300 to 18200 kg/m2s, outlet subcooling of 27-105 K and critical heat flux of 2.0 - 18.1 MW/m2. The experimental conditions are listed in Tab.3.
No | Diameters D2/D1 (mm) | Length L (mm) | Pressure P (MPa) | Mass flux G (Mg/m2s) | subcooling △Ts (K) | Number of data |
1 | 16/12 | 260-400 | 0.17-1.31 | 2.8-18.2 | 34-89 | 67* |
2 | 32/28 | 300 | 0.24-1.21 | 2.8-12.4 | 35-98 | 46**+27* |
3 | 32/27.6 | 300 | 0.3-1.1 | 3.5-12.1 | 29-84 | 230* |
4 | 32/26.8 | 275-400 | 0.28-1.1 | 2.9-13.0 | 37-102 | 67* |
5 | 32/26 | 300 | 0.36-0.85 | 3.6-12.7 | 37-70 | 47* |
6 | 32/24 | 300 | 0.18-1.8 | 1.3-8.0 | 27-105 | 61* |
7 | 70/66 | 255 | 0.25-0.4 | 2.9-7.0 | 26-54 | 15* |
8 | 70/65 | 255 | 0.25-0.37 | 3.2-5.7 | 34-49 | 18* |
The velocity and subcooling have predominant effects on the CHF. Under most conditions of interest the effect of pressure is not appreciable. The variation of gap width from 2.0 to 4.0mm does not make an appreciable effect on the CHF. This can probably be explained as follows: larger gap size associates with lower heat transfer coefficient to the liquid core, as suggested by the turbulent convection heat transfer correlation, on the other hand larger gap size corresponds to higher Reynolds number, which is benefit for the departure of bubbles from heated surface. For the present conditions these two opposite factors would be comparative, making the CHF not sensitive to the gap size. These results are consistent with many similar experiments (see Tab.1).
In the present experiment the effect of curvature of heated surface is not observed. This is understandable, because the curvature of heated surface is small, compared to the bubble, and it could not have a noticeable effect on the bubble behavior.
For the sake of simplicity in engineering applications, the effects of pressure, diameter and gap width are ignored, and the experimental data are formulated as the following empiric correlation
The comparison of calculation of Eq.(3) with the experimental data is shown in Fig.10. The AVG and RMS are -0.01 and 0.083, respectively.
Bilateral-side heating (Chen, et al., 1996)
Experiment was performed in a stainless-steel annulus of D1=28 mm and D2=35.7 mm and heating length of 160 mm with bilateral-side heating. The critical heat flux data were obtained at the outer wall. The conditions cover the range of pressure of 0.31 – 0.39 MPa, velocity of 2.55 – 8.12 mm, subcooling of 49.1 – 76.6 K and the ratio of inner to outer-wall heat fluxes of q1/q2 of 0 – 0.94.
For convenience in comparison, the result of outer-side heating is formulated by
as shown in Fig.11.
The experimental results of bilateral-side heating are displayed in Fig.12 by plotting the ratio of qc/qc,0 against q1/q2 (1 and 2 denote the inner-wall and outer-wall, respectively). As seen, the critical heat flux exhibits an increase trend with q1/q2 increasing. When q1/q2 closes to 1.0 the CHF is increased by 15 – 20%. It can be attributed to the variation of temperature profile in liquid core, which results in an increase in condensation efficiency of the bubbly layer by subcooled liquid core, that is similar with that in single-phase convection heat transfer. This effect can be clarified further by the model analysis latter in paragraph 4.3.
3.2.3. Transient CHF (Chen et al., 2005)
Critical heat flux is more likely to occur under off-normal or accident conditions, in which a transient would experiences of flow rate, pressure and/or power. Many studies have focused on the transient CHF (Leung, 1978, Chang, et al., 1989, Iwamura, et al., 1987, 1994, Celata, et al., 1991, Weisman, 1993, Moon, et al., 2002). In higher quality region the experimental results revealed the inadequacy of the steady-state CHF correlation for transient conditions. While in subcooled and low quality region, the effect of transient on the CHF was found not appreciable. In general, the transient CHF has not been studied adequately for wider range of condition, and in evaluation of nuclear reactor safety the CHF for transient conditions is predicted with the correlations derived at steady-state conditions (IAEA-TECDOC-1203, 2001).
In the present study an experiment of flow-reduction transient CHF was performed in a stainless-steel tube of 15.9 mm in diameter, covering the range of pressure of 0.2 - 1.4 MPa, initial velocity of 4.5 - 13.5 m/s, and the initial inlet subcooling of 80 – 160 K. The flow rate was reduced linearly as
where
The experimental results are shown in Fig.13, in which the P, V and △Ts are the instantaneous values. For P > 1.0 MPa the effect of flow transient on CHF appears not prominent. For P < 0.3 MPa, in high subcooling region the effect of transient is not appreciable, while for subcooling lower than about 50 K the result departs from the trend of steady-state distinctly, and higher CHF is attained at higher flow reduction rate.
Different effect on the CHF observed at different conditions can probably be explained by different mechanisms of the CHF. For low subcooling the CHF is induced by a limit of enthalpy of bubbly layer, while for high subcooling the CHF is induced by a limit of bubbly-layer condensation by the subcooled liquid core (Thorogerson et al., 1974). Compared to the steady-state, at a flow-reduction transient with constant heat flux and constant subcooling the enthalpy in the bubbly layer is higher and the temperature in the liquid core is lower. At high subcooling the thickness of bubbly layer is small, thus for a constant CHF the subcooling would not be different greatly from the steady-state. While at low subcooling the thickness of bubbly layer is larger, and a constant CHF would occur at a higher subcooling than that of steady-state. It would lead to the premature of the OSV, associated with prominent effect on the CHF, as observed at low pressure.
Fig 14 shows the variation of pressure drop before the onset of CHF in flow-reduction transients of p =0.23 MPa and k = 0.24 with heat flux of q = 890, 775 and 750 W/cm2 for run iii, iv and v respectively. In run iii, the pressure drop exhibits a monotonous decrease with flow rate decrease, until the onset of CHF. While in run iv and v, before the onset of CHF the decrease of pressure drop is followed by a sharp increase. In these three runs the CHF are higher than those of steady-state by about 5%, 18% and 36%. The critical subcoolings are 54.7, 46.5 and 37 K respectively, all of which are higher than the values of steady-state, evidencing the premature of OSV.
4. Physical model
4.1. Mechanism
In subcooled flow boiling the enthalpy of bubbly layer is determined by the heat transfer from the interface of bubbly layer to the liquid core, and the excessive bubble crowding serves as a thermal shield, leading to the onset of CHF. For the DNB with low subcooling or saturated condition, the critical enthalpy models were proposed by Weisman and Pei (1983) and Tong (1968), in which the heat transfer coefficient from the interface of bubbly layer to liquid core was estimated by correlations derived from their experiments. For the DNB with high subcooling, the liquid sublayer dryout models were proposed by Katto (1992), Lee and Mudawar (1983) and Celata et al. (1994), in which the bubble diameter, the thickness of liquid sublayer and the length of vapor blanket were determinant for the sublayer dryout.
For higher subcooling the major part of heat from wall is transferred to the liquid core and a minor part for increase of the enthalpy of bubbly layer. Therefore, the characteristic of bubbly layer is primarily controlled by the heat transfer from the bubbly layer to liquid core. This heat transfer is closely relative to the turbulence near the edge of bubbly layer, and is sensitive to the distance from the wall. The increase in thickness of bubbly layer has positive effect on the CHF due to increase in the heat transfer efficiency to liquid core, but negative effect due to increase in the thermal resistance of the bubbly layer. The balance of these two factors gives a critical value of the thickness. Therefore, in the liquid sublayer dryout model the thickness of bubbly layer is a determinant factor.
4.2. Model for tube (Chen et al., 2011)
The model is based on the mechanism of liquid sublayer dryout by modifying the Celata’s model for the thickness of bubbly layer to cover both high and low subcooling region.
Bubbly layer
At high flow and high subcooling the minimum thickness of bubbly layer is determined by the size of a bubble, while at low subcooling it could be larger due to bubble crowding. For the present experimental condition the following expression on the thickness of bubbly layer is attempted,
where the factor
where
and
where p is the pressure in MPa.
The friction factor,
where D is the tube diameter, Re the Reynolds number,
Liquid core
The velocity distribution in the liquid core is represented by Karman’s universal law, as in Celata’s model,
with
and
where
The temperature distribution in the liquid core is as follows (Martinelli, 1947),
with
Equations (5) to (7) are assumed valid in the region of
Calculation of critical heat flux
The local enthalpy,
where
and
where
where r is the radius of tube, and
The exit enthalpy,
where
Calculation is started with a test heat flux
To get the calculations better fit to the experimental data, the constants in Eq. (4) are as:
The experimental data in tubes are calculated by the present model. The comparison is shown in Fig.15 and 16 for p > 2 MPa and < 2 MPa, respectively.
4.3. Model for annulus (Chen et al., 1996)
Fig.17 shows schematically the profiles of velocity and temperature in the liquid core of an annulus. Some assumptions are made as follows:
Each wall is heated uniformly, and the flow and heat transfer conditions are fully developed;
At the edge of liquid bubbly layer the heat flux is equal to that of outer-wall
In liquid core the properties are evaluated at the bulk temperature.
In liquid core the energy balance equation is written as
with
For fully developed flow with uniform heating, the
The average bulk temperature is approximated by
Integrating Eq.(16) by parts gives
where
By assuming
The velocity distribution is assumed in power law, as
where r1 and r2 are the radius of inner and outer wall, respectively, and rm is the radius of maximum velocity
where
The friction factor is estimated by (Xu et al., 1979)
with
The momentum eddy diffusivity is evaluated by (Levy, 1967)
with
and
The turbulent Prandtl number,
Both the experimental data of 8 annuli with single-side heating and the annulus with bilateral-side heating are predicted by this model. The comparison is shown in Fig.18 to 20.
5. Summary
Critical heat flux is an important subject to many applications. Especially for nuclear reactors, it is a major limit for the safety. The CHF has been investigated extensively over the world, and various prediction methods have been available. Unfortunately, there exists a scarcity of experimental data in certain regions. Because of extreme complexity of the phenomenon and the lack of adequate knowledge of the mechanisms, all these predictive methods are heavily relied on the experimental data, and can not be extrapolated out of the range with confidence.
In the present lab a great number of critical heat flux data of subcooled water have been obtained in tubes and annuli with different diameter and gap size over wide range of parameters with emphasis on lower pressure and higher pressure with low flow. The results fill the gap of database and the knowledge of the phenomenon.
The velocity and subcooling are the predominant parameters for the CHF. At lower pressure these effects are stronger. At the pressure below 0.3 MPa, when the subcooling decreases below a certain low value the CHF behavior varies substantially as a result of significant voiding. The effect of geometry is related to the pressure, subcooling and velocity. All these effects are inter-dependent, and are hardly to be represented in a single correlation for wide range of conditions. In the present study two models have been developed for the subcooled flow boiling CHF in circular tube and annulus, based on the mechanisms of CHF and the present experimental data. They will be validated and improved for extended range of conditions.
Nomenclature
D diameter
△Ts subcooling
G mass flux
U
V average liquid velocity at CHF
Prt turbulent Prandtl numbe
Re Reynolds number
W channel width
Subscript
c critical, calculatiom
M measurement
s saturation
1 inner-wall
2 outer-wall
References
- 1.
Berglest A. E. 1977 Burnout in Boiling Heat Transfer, Part II: Subcooled and Low-Quality Forced-Convection System, Nuclear Safety,18 N2,154 167 - 2.
Chang S. H. Lee K. W. Groeneveld D. C. 1989 Transient-Effects Modelling of Critical Heat Flu x, Nucl. Eng. Design,113 51 57 - 3.
Celata G. P. Cumo M. D’annibale F. Farello G. E. Mariani A. 1991 CHF Behavior During Pressure, Power and/or Flow Rate Simultaneous Variations, Int. J. Heat Mass Transfer, 34(3).723 738 - 4.
Celata G. P. Cuma M. Mariani A. Simosini M. Zummo G. 1994 Rationalization of Existing Mechanistic Models for the Prediction of Water Subcooled Flow Boiling Critical Heat Flux Int. J. Heat and Mass Transfer37 Suppl. 1,347 360 - 5.
Chen Y. Zhou R. Chen H. 1996 Critical Heat Flux for Subcooled Flow in an Annulus with Bilateral Heating, in Heat Transfer and Technology 1996, Bu-xuan Wang, Higher Education. Press,7-04005-894-4 376 381 - 6.
Chen Y. Zhou R. Hao L. Chen H. 1997 Critical Heat Flux with Subcooled Boiling of Water at Low Pressure, Proc. 8th Int. Topical Meeting on Nuclear Reactor Thermal-Hydraulics, 1997, Japan,2 958 964 - 7.
Chen Y. Zhang H. Guo F. Hao L. 2000 Subcooled Flow Boiling CHF in Tubes with Different Diameters, Presented at Boiling 2000, Alaska - 8.
Chen Y. Zou L. Yang C. 2004 Subcooled Critical Heat Flux in Annuli at Lower Pressure, Proc. NUTHOS-5, Japan - 9.
Chen Y. Yang C. Mao Y. 2005 An Experimental Study of Subcooled Flow Boiling Critical Heat Flux of Water under Steady-State and Flow-Transient Conditions at Lower Pressure, Proc. 11th Int. Topical Meeting on Nuclear Reactor Thermal-Hydraulics (NURETH-11), Avignon, France - 10.
Chen Y. Yang C. Zhao M. Bi K. Du K. Zhang S. 2011 Subcooled Boiling Critical Heat Flux of Water Flowing Upward in a Tube for Lower Flow and Pressure up to 20 MPa, Proc. 14th Int. Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-14), LN-620 - 11.
Gambill W. R. 1963 Generalized Prediction of Burnout Heat Flux for Flowing Subcooled Wetting Liquids, Chem. Eng. Prog. Sump. Series,59 41 - 12.
Groeneveld D. C. et al. 1996 The 1996 Look-up Table for Critical Heat Flux in Tubes, Nuclear Eng. Design163 1 23 - 13.
Gunther F. C. 1951 Photographic Study of Surface Boiling Heat Transfer to Water with Forced Convection, Trans. ASME,73 115 - 14.
Iwamura T. 1987 Transient Burnout Under Rapid Flow Reduction Condition J. Nucl. Sci. and Tech.24 811 820 - 15.
Iwamura T. Watanabe H. Murao Y. 1994 Critical Heat Flux Experiments under Steady-state and Transient Conditions and Visualization of CHF Phenomenon with Neutron Radiography Nuclear Engineering and Design149 195 206 - 16.
Katto Y. 1992 A Prediction Model of Subcooled Water Flow Boiling CHF for Pressures in the region 0.1-20.0 MPa, Int. J. Heat ans Mass Transfer,35 1115 1123 - 17.
Klausner J. F. Mei R. Bernhard D. M. Zeng L. Z. 1993 Vapor Bubble Departure in Forced Convection Boiling Int. J. Heat Mass Transfer,36 651 662 - 18.
Knoebel D. H. Harris S. D. Crain B. 1973 Forced Convection Subcooled Critical Heat Flux, D2O and H2O Coolant with Aluminum and Stainless-Steel Heaters, DP- 1306 - 19.
Levy S. 1967 Turbulent Flow in an Annulus Trans. ASME, C, J. Heat Transfer,89 25 31 - 20.
Lee C. H. Mudawar I. 1983 A Mechanistic Critical Heat Flux Model for Subcooled Flow Boiling Based on Local Bulk Flow Conditions Int. J. Multiphase Flow,14 711 728 - 21.
Leung J. C. M. 1978 CHF under Transient Conditions: a Literature survey," NURETH/CP-0056 - 22.
Martinelli R. C. 1947 Heat Transfer to Molter Metals”, Trans. ASME69 947 951 - 23.
Mirshak S. Durant W. S. Towell R. H. 1959 Heat Flux at Burnout DP- 355 - 24.
Moon S. K. Chun S. Y. Choi K. Y. Baek W. P. 2002 Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution, J. Korea Nuclear Science,34 382 395 - 25.
Siman-Tov M. Felde D. K. Mc Duffee J. L. Yoder Jr G. L. 1995 Static Flow-instability in Subcooled Flow Boiling in Wide Rectangular Parallel Channels, 2nd Int. Conf. on Multi-phase Flow, Japan - 26.
Staub F. W. 1968 The Void Fraction in Subcooled Boiling- Prediction of the initial Point of Net Vapor Generation, J. Heat Transfer,90 151 157 - 27.
Sudo Y. Kaminaga M. 1993 ANew CHF Correlation Scheme Proposed for Vertical Rectangular Channels Heated From Both Sides in Nuclear Research Reactors ASME, C.115 426 434 - 28.
Thermohydraulic relationships for advanced water cooled reactors 2001 IAEA-TECDOC-1203 - 29.
Thorogerson E. J. Knoebel D. H. Gibbons J. H. 1974 A Model to Predict Convective Subcooled Critical Heat Flux," Trans. ASME, J. Heat Transfer,96 79 82 - 30.
Tong L. S. 1968 Boundary Layer Analysis of the Flow Boiling Crisis, Int. J. Heat Mass Transfer,11 1208 1211 - 31.
Tong L. S. 1967 Prediction of Departure from Nucleate Boiling for An Axially Non-Uniform Heat Distribution, Jou rnal Nuclear Energy,21 - 32.
Tong L. S. Tang Y. S. 1997 Boiling Heat Transfer and Two-Phase Flow Taylor & Francis Pub.,1-56032-485-6 - 33.
Weisman J. Pei B. S. 1983 Prediction of Critical Heat Flux in Flow Boiling at low qualities J. Heat Mass Transfer,26 1463 1477 - 34.
Weisman J. 1995 A Phenomenological Explanation of the Relationship Between Steady State and Transient CHF at Subcooled or low Quality Conditions Nucl. Eng. and Des.158 157 160 - 35.
al. (Xu G. at 1979 Heat Transfer and Pressure Drop in an Annulus with Subcooled Boiling Water, Analysis and Experiment of Reactor Thermohydraulics, Atomic Energy Press,412 417 in Chinese) - 36.
Zeigarnik Yu. A. 1994 Critical Heat Flux with Boiling of Subcooled Water in Rectangular Channels with One Sided Supply of Heat Thermal Engineering,28 40